Antibody Raw Material · OEM Ready · Rapid Test

Strep A Antibody Pair

10× More Sensitive Lateral Flow Antibody Pair for Group A Streptococcus Rapid Antigen Detection

LFAStrep AGASPharyngitisOEM
2×10²
cfu/mL LoD
100%
Specificity
10×
More Sensitive
5–15 min
Time-to-Result

Next-Generation Sensitivity for GAS Rapid Antigen Detection

The Strep A Antibody Pair is a high-sensitivity capture/detection antibody system for Group A Streptococcus (GAS, Streptococcus pyogenes) rapid antigen testing. With a limit of detection of 2×10² cfu/mL — 10 times lower than the conventional standard of 2×10³ cfu/mL — this antibody pair detects early-stage and low-burden GAS infections that are missed by standard rapid antigen tests.

Validated on 100 clinical and analytical samples with 100% analytical specificity, the pair targets a conserved GAS cell wall antigen expressed across multiple M-protein serotypes. Available as OEM raw material for lateral flow rapid test manufacturers.

Lateral Flow LFA10× Sensitivity AdvantageISO 13485 ManufacturerOEM Antibody Pair Available

Analytical Specifications

Assay FormatLateral Flow Immunoassay (LFA)
Target AntigenGroup A Streptococcus (GAS) surface antigen
Sample TypeThroat swab
Limit of Detection2×10² cfu/mL
vs. Conventional LOD2×10³ cfu/mL (10× improvement)
Analytical Specificity100% (n=50 non-GAS / healthy samples)
Time-to-Result5–15 minutes
Serotype CoverageBroad-spectrum (multiple GAS serotypes)

Clinical-Grade Sensitivity for Rapid GAS Detection

Analytical and clinical advantages that make this the right antibody pair for next-generation Strep A rapid tests.

10× Lower Detection Limit

LOD of 2×10² cfu/mL — 10-fold lower than the conventional 2×10³ cfu/mL threshold. Detects early-stage and low-burden GAS infections that would be missed by standard rapid antigen tests.

100% Analytical Specificity

50 non-GAS and healthy throat swab samples tested; zero false positives. No cross-reactivity with other streptococcal groups (B, C, G) or common respiratory pathogens.

Rapid 5–15 Minute Result

Single-step lateral flow format delivers visual and reader-based results in 5–15 minutes — enabling antibiotic stewardship decisions within the clinical consultation.

Broad Serotype Coverage

Antibody pair targets conserved GAS cell wall antigen epitopes present across multiple M-protein serotypes, ensuring detection regardless of regional strain variation.

Antibiotic Stewardship Support

Differentiates GAS pharyngitis (requiring antibiotics) from viral pharyngitis (antibiotics contraindicated) — reducing unnecessary antibiotic prescriptions and preventing resistance development.

OEM Antibody Pair Available

Capture and detection antibodies available as OEM raw material for licensed rapid test manufacturers. Optimized for nitrocellulose membrane LFA and compatible with visual and reader-based readout.

Analytical & Clinical Data

All data generated using Sekbio anti-GAS monoclonal antibody pair in lateral flow sandwich format.

1 Analytical Sensitivity — Limit of Detection

Gradient dilution series of Strep A antigen (starting from 2×10⁹ cfu/mL) were tested to determine the minimum detectable concentration. The Sekbio Strep A antibody pair achieves a 10-fold lower LOD compared to conventional rapid antigen tests.

Test FormatLimit of DetectionComparison
Conventional Strep A Rapid Test2×10³ cfu/mLReference standard
Sekbio Strep A Antibody Pair2×10² cfu/mL10× more sensitive
LOD determined by gradient dilution of GAS antigen (2×10⁹ cfu/mL stock). Positive/negative threshold defined as visible test line.
2 Analytical Specificity

One hundred throat swab samples were evaluated: 50 non-GAS/healthy samples and 50 GAS-positive samples. The Sekbio Strep A pair demonstrates complete analytical specificity with zero cross-reactivity.

Sample Typen TestedExpected ResultObserved ResultConcordance
Non-GAS / Healthy samples50Negative50 Negative100%
GAS-positive samples50PositivePositive (LOD-dependent)
Non-GAS samples include specimens from Group B, C, G Streptococcus and common respiratory viral pathogens. Zero false positives observed.
3 Clinical Significance of Enhanced Sensitivity

Group A Streptococcus pharyngitis affects over 600 million people globally per year. Early, low-burden GAS infections — detectable at 2×10² cfu/mL — are clinically important as untreated Strep A can progress to rheumatic fever and glomerulonephritis.

Clinical impact: The 10-fold sensitivity advantage of the Sekbio Strep A antibody pair is clinically significant: patients with early GAS infection (burden 2×10²–10³ cfu/mL) who test negative on conventional rapid tests can now be correctly identified and treated, reducing risk of post-streptococcal complications.

Applications

The GAS antibody pair is validated for OEM lateral flow rapid test development and multiple clinical testing contexts.

Pharyngitis & Tonsillitis Diagnosis

Rapid point-of-care differentiation of GAS bacterial pharyngitis from viral infection — enabling immediate, guideline-concordant antibiotic prescribing decisions within the consultation.

Pediatric & School Health Screening

Children aged 5–15 are the highest-risk group for GAS infection and post-streptococcal complications. Rapid testing enables same-visit treatment and limits transmission in school settings.

Emergency & Primary Care Triage

5–15 minute result turnaround supports urgent triage in emergency departments, urgent care centers, and community health clinics where culture-based testing is not feasible.

OEM Rapid Test Manufacturing

GAS capture and detection antibody pair available for licensed IVD manufacturers developing Strep A rapid antigen tests. ISO 13485-compliant supply chain with consistent lot performance.

Ready to Build a Better Strep A Test?

Request the full technical datasheet, antibody pair specifications, or discuss OEM supply and rapid test development with our team.